NVMe SMART Log
To obtain the Quadra device NVMe SMART log, use the following command:
sudo nvme smart-log /dev/nvme0
Here is an example of the output:
Smart Log for NVME device:nvme0 namespace-id:ffffffff
critical_warning : 0
temperature : 38 C
available_spare : 100%
available_spare_threshold : 20%
percentage_used : 0%
data_units_read : 0
data_units_written : 0
host_read_commands : 0
host_write_commands : 0
controller_busy_time : 0
power_cycles : 0
power_on_hours : 0
unsafe_shutdowns : 0
media_errors : 0
num_err_log_entries : 0
Warning Temperature Time : 0
Critical Composite Temperature Time : 0
Temperature Sensor 1 : 38 C
Temperature Sensor 2 : 41 C
Thermal Management T1 Trans Count : 0
Thermal Management T2 Trans Count : 0
Thermal Management T1 Total Time : 0
Thermal Management T2 Total Time : 0
Below is an explanation of the sensors:
| Temperature Sensor 1 | represents the board temperature. |
| Temperature Sensor 2 | represents the on die temperature. |
| temperature | represents the composite temperature. |
When determining throttling behavior, the composite temperature is used.